Re: Synchronizing slots from primary to standby
shveta malik <shveta.malik@gmail.com>
Attachments
- v63-0004-Allow-logical-walsenders-to-wait-for-the-physica.patch (application/octet-stream) patch v63-0004
- v63-0003-Slot-sync-worker-as-a-special-process.patch (application/octet-stream) patch v63-0003
- v63-0001-Enable-setting-failover-property-for-a-slot-thro.patch (application/octet-stream) patch v63-0001
- v63-0005-Non-replication-connection-and-app_name-change.patch (application/octet-stream) patch v63-0005
- v63-0002-Add-logical-slot-sync-capability-to-the-physical.patch (application/octet-stream) patch v63-0002
- v63-0006-Document-the-steps-to-check-if-the-standby-is-re.patch (application/octet-stream) patch v63-0006
On Wed, Jan 17, 2024 at 3:08 PM Bertrand Drouvot
<bertranddrouvot.pg@gmail.com> wrote:
>
> Hi,
>
> On Tue, Jan 16, 2024 at 05:27:05PM +0530, shveta malik wrote:
> > PFA v62. Details:
>
> Thanks!
>
> > v62-003:
> > It is a new patch which attempts to implement slot-sync worker as a
> > special process which is neither a bgworker nor an Auxiliary process.
> > Here we get the benefit of converting enable_syncslot to a PGC_SIGHUP
> > Guc rather than PGC_POSTMASTER. We launch the slot-sync worker only if
> > it is hot-standby and 'enable_syncslot' is ON.
>
> The implementation looks reasonable to me (from what I can see some parts is
> copy/paste from an already existing "special" process and some parts are
> "sync slot" specific) which makes fully sense.
>
> A few remarks:
>
> 1 ===
> + * Was it the slot sycn worker?
>
> Typo: sycn
>
> 2 ===
> + * ones), and no walwriter, autovac launcher or bgwriter or slot sync
>
> Instead? "* ones), and no walwriter, autovac launcher, bgwriter or slot sync"
>
> 3 ===
> + * restarting slot slyc worker. If stopSignaled is set, the worker will
>
> Typo: slyc
>
> 4 ===
> +/* Flag to tell if we are in an slot sync worker process */
>
> s/an/a/ ?
>
> 5 === (coming from v62-0002)
> + Assert(tuplestore_tuple_count(res->tuplestore) == 1);
>
> Is it even possible for the related query to not return only one row? (I think the
> "count" ensures it).
>
> 6 ===
> if (conninfo_changed ||
> primary_slotname_changed ||
> + old_enable_syncslot != enable_syncslot ||
> (old_hot_standby_feedback != hot_standby_feedback))
> {
> ereport(LOG,
> errmsg("slot sync worker will restart because of"
> " a parameter change"));
>
> I don't think "slot sync worker will restart" is true if one change enable_syncslot
> from on to off.
>
> IMHO, v62-003 is in good shape and could be merged in v62-002 (that would ease
> the review). But let's wait to see if others think differently.
>
> Regards,
>
> --
> Bertrand Drouvot
> PostgreSQL Contributors Team
> RDS Open Source Databases
> Amazon Web Services: https://aws.amazon.com
PFA v63.
--It addresses comments by Peter given in [1], [2], comment by Nisha
given in [3], comments by Bertrand given in [4]
--It also moves race-condition fix from patch003 to patch002 as
suggested by Swada-san offlist. Race-condition is mentioned in [5]
All the changes are in patch02, patch003 and patch006.
[1]: https://www.postgresql.org/message-id/CAHut%2BPuECB8fNBfXMdTHSMKF9kL%3D0XqPw1Am4NVahfJSSHzoYg%40mail.gmail.com
[2]: https://www.postgresql.org/message-id/CAHut%2BPt0uum%2B6Hg5UDofWMEJWhVEyArM1b0_B94UJmRcQmz7DA%40mail.gmail.com
[3]: https://www.postgresql.org/message-id/CABdArM73qdHyA0nteDLAQrfKNHRP%2B5Qq6p8uobg5bkE3EWiC%2Bg%40mail.gmail.com
[4]: https://www.postgresql.org/message-id/ZaegJe9JpUiQeV%2BD%40ip-10-97-1-34.eu-west-3.compute.internal
[5]: https://www.postgresql.org/message-id/CAD21AoA5izeKpp9Ei4Cd745pKX3wn-TRvhhmPFEW9UY1nx%2B_aw%40mail.gmail.com
thanks
Shveta
Commits
-
Doc: Add the new section "Logical Replication Failover".
- b560a98a17ae 17.0 landed
-
Fix the review comments and a bug in the slot sync code.
- 3741f2a09d52 17.0 landed
-
Fix a test in failover slots regression test.
- 7e85d1c75f29 17.0 landed
-
Fix the intermittent buildfarm failures in 040_standby_failover_slots_sync.
- 6f3d8d5e7cc2 17.0 landed
-
Split XLogCtl->LogwrtResult into separate struct members
- c9920a9068ea 17.0 cited
-
Ensure that the sync slots reach a consistent state after promotion without losing data.
- 2ec005b4e297 17.0 landed
-
Introduce a new GUC 'standby_slot_names'.
- bf279ddd1c28 17.0 landed
-
Fix BF failure introduced by commit b3f6b14cf4.
- def0ce337068 17.0 landed
-
Fixups for commit 93db6cbda0.
- b3f6b14cf48f 17.0 landed
-
Fix BF failure in commit 93db6cbda0.
- d13ff82319cc 17.0 landed
-
Add a new slot sync worker to synchronize logical slots.
- 93db6cbda037 17.0 landed
-
Improve ERROR/LOG messages added by commits ddd5f4f54a and 7a424ece48.
- 801792e528d6 17.0 landed
-
Disable autovacuum on primary in 040_standby_failover_slots_sync test.
- b7bdade6a42f 17.0 landed
-
Fix the incorrect format specifier used in commit 7a424ece48.
- b987be39c3c7 17.0 landed
-
Change the LOG level in 040_standby_failover_slots_sync.pl to DEBUG2.
- d9e225f275b7 17.0 landed
-
Add more LOG and DEBUG messages for slot synchronization.
- 7a424ece4828 17.0 landed
-
Another try to fix BF failure introduced in commit ddd5f4f54a.
- 9bc1eee988c3 17.0 landed
-
Fix BF introduced in commit ddd5f4f54a.
- bd8fc1677b88 17.0 landed
-
Add a slot synchronization function.
- ddd5f4f54a02 17.0 landed
-
Clean-ups for 776621a5e4 and 7329240437.
- 22f7e61a6330 17.0 landed
-
Enhance libpqrcv APIs to support slot synchronization.
- dafbfed9efbe 17.0 landed
-
Add a failover option to subscriptions.
- 776621a5e479 17.0 landed
-
Allow setting failover property in the replication command.
- 73292404370c 17.0 landed
-
Allow to enable failover property for replication slots via SQL API.
- c393308b69d2 17.0 landed
-
Add macros for looping through a List without a ListCell.
- 14dd0f27d7cd 17.0 cited
-
Track conflict_reason in pg_replication_slots.
- 007693f2a3ac 17.0 cited
-
Allow upgrades to preserve the full subscription's state.
- 9a17be1e244a 17.0 cited
-
Add support for incremental backup.
- dc212340058b 17.0 cited
-
Simplify some logic in CreateReplicationSlot()
- e83aa9f92fdd 17.0 cited
-
Fix uninitialized access to InitialRunningXacts during decoding after ERROR.
- c7256e6564fa 15.5 cited
-
Flexible options for CREATE_REPLICATION_SLOT.
- 0266e98c6b86 15.0 cited
-
Empty search_path in logical replication apply worker and walsender.
- 11da97024abb 14.0 cited
-
Fix oldest xmin and LSN computation across repslots after advancing
- b48df818dcbd 14.0 cited
-
Require C99 (and thus MSCV 2013 upwards).
- d9dd406fe281 12.0 cited