Re: Introduce XID age and inactive timeout based replication slot invalidation

Bertrand Drouvot <bertranddrouvot.pg@gmail.com>

From: Bertrand Drouvot <bertranddrouvot.pg@gmail.com>
To: Bharath Rupireddy <bharath.rupireddyforpostgres@gmail.com>
Cc: shveta malik <shveta.malik@gmail.com>, Amit Kapila <amit.kapila16@gmail.com>, Nathan Bossart <nathandbossart@gmail.com>, PostgreSQL Hackers <pgsql-hackers@lists.postgresql.org>
Date: 2024-03-27T10:11:58Z
Lists: pgsql-hackers

Commits

Same data as JSON: GET /api/v1/messages/:b64id/commits the thread's linked commits as JSON, with link sources. API reference →
  1. Add a test for commit ac0e33136a using the injection point.

  2. Invalidate inactive replication slots.

  3. Fix incorrect slot type in BuildTupleHashTableExt

  4. Allow synced slots to have their inactive_since.

  5. Change last_inactive_time to inactive_since in pg_replication_slots.

  6. Track last_inactive_time in pg_replication_slots.

  7. Track invalidation_reason in pg_replication_slots.

  8. Add option force_initdb to PostgreSQL::Test::Cluster:init()

  9. Add a failover option to subscriptions.

  10. Allow setting failover property in the replication command.

  11. Allow to enable failover property for replication slots via SQL API.

  12. Track conflict_reason in pg_replication_slots.

  13. Log messages for replication slot acquisition and release.

  14. Remove vacuum_defer_cleanup_age

  15. Fix corruption due to vacuum_defer_cleanup_age underflowing 64bit xids

  16. meson: Add initial version of meson based build system

Hi,

On Wed, Mar 27, 2024 at 02:55:17PM +0530, Bharath Rupireddy wrote:
> Please check the attached v27 patch which also has Bertrand's comment
> on deduplicating the TAP function. I've now moved it to Cluster.pm.

Thanks!

1 ===

+        Note that the slots on the standbys that are being synced from a
+        primary server (whose <structfield>synced</structfield> field is
+        <literal>true</literal>), will get the
+        <structfield>inactive_since</structfield> value from the
+        corresponding remote slot on the primary. Also, note that for the
+        synced slots on the standby, after the standby starts up (i.e. after
+        the slots are loaded from the disk), the inactive_since will remain
+        zero until the next slot sync cycle.

Not sure we should mention the "(i.e. after the slots are loaded from the disk)"
and also "cycle" (as that does not sound right in case of manual sync).

My proposal (in text) but feel free to reword it:

Note that the slots on the standbys that are being synced from a
primary server (whose synced field is true), will get the inactive_since value
from the corresponding remote slot on the primary. Also, after the standby starts
up, the inactive_since (for such synced slots) will remain zero until the next
synchronization.

2 ===

+=item $node->create_logical_slot_on_standby(self, primary, slot_name, dbname)

get_slot_inactive_since_value instead?

3 ===

+against given reference time.

s/given reference/optional given reference/?


Apart from the above, LGTM.

Regards,

-- 
Bertrand Drouvot
PostgreSQL Contributors Team
RDS Open Source Databases
Amazon Web Services: https://aws.amazon.com