RE: Synchronizing slots from primary to standby
Zhijie Hou (Fujitsu) <houzj.fnst@fujitsu.com>
Attachments
- v61-0002-Add-logical-slot-sync-capability-to-the-physical.patch (application/octet-stream) patch v61-0002
- v61-0003-Allow-logical-walsenders-to-wait-for-the-physica.patch (application/octet-stream) patch v61-0003
- v61-0004-Non-replication-connection-and-app_name-change.patch (application/octet-stream) patch v61-0004
- v61-0001-Enable-setting-failover-property-for-a-slot-thro.patch (application/octet-stream) patch v61-0001
On Friday, January 12, 2024 8:00 PM Masahiko Sawada <sawada.mshk@gmail.com> wrote:
Hi,
>
> On Thu, Jan 11, 2024 at 7:53 PM Amit Kapila <amit.kapila16@gmail.com> wrote:
> >
> > On Tue, Jan 9, 2024 at 6:39 PM Amit Kapila <amit.kapila16@gmail.com> wrote:
> > >
> > > +static bool
> > > +synchronize_one_slot(WalReceiverConn *wrconn, RemoteSlot
> > > +*remote_slot)
> > > {
> > > ...
> > > + /* Slot ready for sync, so sync it. */ else {
> > > + /*
> > > + * Sanity check: With hot_standby_feedback enabled and
> > > + * invalidations handled appropriately as above, this should never
> > > + * happen.
> > > + */
> > > + if (remote_slot->restart_lsn < slot->data.restart_lsn) elog(ERROR,
> > > + "cannot synchronize local slot \"%s\" LSN(%X/%X)"
> > > + " to remote slot's LSN(%X/%X) as synchronization"
> > > + " would move it backwards", remote_slot->name,
> > > + LSN_FORMAT_ARGS(slot->data.restart_lsn),
> > > + LSN_FORMAT_ARGS(remote_slot->restart_lsn));
> > > ...
> > > }
> > >
> > > I was thinking about the above code in the patch and as far as I can
> > > think this can only occur if the same name slot is re-created with
> > > prior restart_lsn after the existing slot is dropped. Normally, the
> > > newly created slot (with the same name) will have higher restart_lsn
> > > but one can mimic it by copying some older slot by using
> > > pg_copy_logical_replication_slot().
> > >
> > > I don't think as mentioned in comments even if hot_standby_feedback
> > > is temporarily set to off, the above shouldn't happen. It can only
> > > lead to invalidated slots on standby.
> > >
> > > To close the above race, I could think of the following ways:
> > > 1. Drop and re-create the slot.
> > > 2. Emit LOG/WARNING in this case and once remote_slot's LSN moves
> > > ahead of local_slot's LSN then we can update it; but as mentioned in
> > > your previous comment, we need to update all other fields as well.
> > > If we follow this then we probably need to have a check for
> > > catalog_xmin as well.
> > >
> >
> > The second point as mentioned is slightly misleading, so let me try to
> > rephrase it once again: Emit LOG/WARNING in this case and once
> > remote_slot's LSN moves ahead of local_slot's LSN then we can update
> > it; additionally, we need to update all other fields like two_phase as
> > well. If we follow this then we probably need to have a check for
> > catalog_xmin as well along remote_slot's restart_lsn.
> >
> > > Now, related to this the other case which needs some handling is
> > > what if the remote_slot's restart_lsn is greater than local_slot's
> > > restart_lsn but it is a re-created slot with the same name. In that
> > > case, I think the other properties like 'two_phase', 'plugin' could
> > > be different. So, is simply copying those sufficient or do we need
> > > to do something else as well?
> > >
> >
> > Bertrand, Dilip, Sawada-San, and others, please share your opinion on
> > this problem as I think it is important to handle this race condition.
>
> Is there any good use case of copying a failover slot in the first place? If it's not
> a normal use case and we can probably live without it, why not always disable
> failover during the copy? FYI we always disable two_phase on copied slots. It
> seems to me that copying a failover slot could lead to problems, as long as we
> synchronize slots based on their names. IIUC without the copy, this pass should
> never happen.
Thanks for the suggestion. I also don't have a use case for this.
Attach the V61 patch set that addresses this suggestion. And here is the
summary of the changes made in each patch.
V61-0001
1. Reverts the changes in copy_replication_slot.
V61-0002
1. Adds the documents for the steps that user needs to follow to ensure the
standby is ready for failover
2. Directly update the fields restart_lsn/confirmed_flush/catalog_xmin instead
of using APIs like LogicalConfirmReceivedLocation
3. Updates all the fields(two_phase, failover, plugin) when syncing the slots
4. fixes CFbot failures.
5. Some code style adjustment. (pending comments in last version)
6. Remove some unnecessary Assert and variable assignment (off-list comments from Peter)
Thanks Shveta for working on 4 and 5.
V61-0003
1. Some documents update related to standby_slot_names and the steps for
failover.
V61-0004
- No change.
Best Regards,
Hou zj
Commits
-
Doc: Add the new section "Logical Replication Failover".
- b560a98a17ae 17.0 landed
-
Fix the review comments and a bug in the slot sync code.
- 3741f2a09d52 17.0 landed
-
Fix a test in failover slots regression test.
- 7e85d1c75f29 17.0 landed
-
Fix the intermittent buildfarm failures in 040_standby_failover_slots_sync.
- 6f3d8d5e7cc2 17.0 landed
-
Split XLogCtl->LogwrtResult into separate struct members
- c9920a9068ea 17.0 cited
-
Ensure that the sync slots reach a consistent state after promotion without losing data.
- 2ec005b4e297 17.0 landed
-
Introduce a new GUC 'standby_slot_names'.
- bf279ddd1c28 17.0 landed
-
Fix BF failure introduced by commit b3f6b14cf4.
- def0ce337068 17.0 landed
-
Fixups for commit 93db6cbda0.
- b3f6b14cf48f 17.0 landed
-
Fix BF failure in commit 93db6cbda0.
- d13ff82319cc 17.0 landed
-
Add a new slot sync worker to synchronize logical slots.
- 93db6cbda037 17.0 landed
-
Improve ERROR/LOG messages added by commits ddd5f4f54a and 7a424ece48.
- 801792e528d6 17.0 landed
-
Disable autovacuum on primary in 040_standby_failover_slots_sync test.
- b7bdade6a42f 17.0 landed
-
Fix the incorrect format specifier used in commit 7a424ece48.
- b987be39c3c7 17.0 landed
-
Change the LOG level in 040_standby_failover_slots_sync.pl to DEBUG2.
- d9e225f275b7 17.0 landed
-
Add more LOG and DEBUG messages for slot synchronization.
- 7a424ece4828 17.0 landed
-
Another try to fix BF failure introduced in commit ddd5f4f54a.
- 9bc1eee988c3 17.0 landed
-
Fix BF introduced in commit ddd5f4f54a.
- bd8fc1677b88 17.0 landed
-
Add a slot synchronization function.
- ddd5f4f54a02 17.0 landed
-
Clean-ups for 776621a5e4 and 7329240437.
- 22f7e61a6330 17.0 landed
-
Enhance libpqrcv APIs to support slot synchronization.
- dafbfed9efbe 17.0 landed
-
Add a failover option to subscriptions.
- 776621a5e479 17.0 landed
-
Allow setting failover property in the replication command.
- 73292404370c 17.0 landed
-
Allow to enable failover property for replication slots via SQL API.
- c393308b69d2 17.0 landed
-
Add macros for looping through a List without a ListCell.
- 14dd0f27d7cd 17.0 cited
-
Track conflict_reason in pg_replication_slots.
- 007693f2a3ac 17.0 cited
-
Allow upgrades to preserve the full subscription's state.
- 9a17be1e244a 17.0 cited
-
Add support for incremental backup.
- dc212340058b 17.0 cited
-
Simplify some logic in CreateReplicationSlot()
- e83aa9f92fdd 17.0 cited
-
Fix uninitialized access to InitialRunningXacts during decoding after ERROR.
- c7256e6564fa 15.5 cited
-
Flexible options for CREATE_REPLICATION_SLOT.
- 0266e98c6b86 15.0 cited
-
Empty search_path in logical replication apply worker and walsender.
- 11da97024abb 14.0 cited
-
Fix oldest xmin and LSN computation across repslots after advancing
- b48df818dcbd 14.0 cited
-
Require C99 (and thus MSCV 2013 upwards).
- d9dd406fe281 12.0 cited