Re: Introduce XID age and inactive timeout based replication slot invalidation

Mihail Nikalayeu <michail.nikolaev@gmail.com>

From: Michail Nikolaev <michail.nikolaev@gmail.com>
To: "Zhijie Hou (Fujitsu)" <houzj.fnst@fujitsu.com>
Cc: Nisha Moond <nisha.moond412@gmail.com>, Amit Kapila <amit.kapila16@gmail.com>, Peter Smith <smithpb2250@gmail.com>, vignesh C <vignesh21@gmail.com>, "Hayato Kuroda (Fujitsu)" <kuroda.hayato@fujitsu.com>, shveta malik <shveta.malik@gmail.com>, Bharath Rupireddy <bharath.rupireddyforpostgres@gmail.com>, Ajin Cherian <itsajin@gmail.com>, Bertrand Drouvot <bertranddrouvot.pg@gmail.com>, Masahiko Sawada <sawada.mshk@gmail.com>, Nathan Bossart <nathandbossart@gmail.com>, PostgreSQL Hackers <pgsql-hackers@lists.postgresql.org>
Date: 2024-12-26T13:56:50Z
Lists: pgsql-hackers

Commits

Same data as JSON: GET /api/v1/messages/:b64id/commits the thread's linked commits as JSON, with link sources. API reference →
  1. Add a test for commit ac0e33136a using the injection point.

  2. Invalidate inactive replication slots.

  3. Fix incorrect slot type in BuildTupleHashTableExt

  4. Allow synced slots to have their inactive_since.

  5. Change last_inactive_time to inactive_since in pg_replication_slots.

  6. Track last_inactive_time in pg_replication_slots.

  7. Track invalidation_reason in pg_replication_slots.

  8. Add option force_initdb to PostgreSQL::Test::Cluster:init()

  9. Add a failover option to subscriptions.

  10. Allow setting failover property in the replication command.

  11. Allow to enable failover property for replication slots via SQL API.

  12. Track conflict_reason in pg_replication_slots.

  13. Log messages for replication slot acquisition and release.

  14. Remove vacuum_defer_cleanup_age

  15. Fix corruption due to vacuum_defer_cleanup_age underflowing 64bit xids

  16. meson: Add initial version of meson based build system

Hello, Hou!

> So, I think it's not a bug in the committed patch but an issue in the
testing
>  venvironment. Besides, since we have not seen such failures on BF, I
think it
>  may not be necessary to improve the testcases.

Thanks for your analysis!
Yes, probably WSL2/Windows interactions cause strange system clock moving.
It looks like it is a common issue with WSL2 [0].

[0]: https://github.com/microsoft/WSL/issues/10006

Best regards,