Re: Introduce XID age and inactive timeout based replication slot invalidation
shveta malik <shveta.malik@gmail.com>
Commits
GET /api/v1/messages/:b64id/commits
the thread's linked commits as JSON, with link sources.
API reference →
-
Add a test for commit ac0e33136a using the injection point.
- 8a695d7998be 18.0 landed
-
Invalidate inactive replication slots.
- ac0e33136abc 18.0 landed
-
Fix incorrect slot type in BuildTupleHashTableExt
- d96d1d5152f3 18.0 cited
-
Allow synced slots to have their inactive_since.
- 6f132ed693b6 17.0 landed
-
Change last_inactive_time to inactive_since in pg_replication_slots.
- 6d49c8d4b4f4 17.0 landed
-
Track last_inactive_time in pg_replication_slots.
- a11f330b5584 17.0 landed
-
Track invalidation_reason in pg_replication_slots.
- 6ae701b4378d 17.0 landed
-
Add option force_initdb to PostgreSQL::Test::Cluster:init()
- ff9e1e764fcc 17.0 cited
-
Add a failover option to subscriptions.
- 776621a5e479 17.0 cited
-
Allow setting failover property in the replication command.
- 73292404370c 17.0 cited
-
Allow to enable failover property for replication slots via SQL API.
- c393308b69d2 17.0 cited
-
Track conflict_reason in pg_replication_slots.
- 007693f2a3ac 17.0 cited
-
Log messages for replication slot acquisition and release.
- 7c3fb505b14e 17.0 cited
-
Remove vacuum_defer_cleanup_age
- 1118cd37eb61 16.0 cited
-
Fix corruption due to vacuum_defer_cleanup_age underflowing 64bit xids
- be504a3e974d 16.0 cited
-
meson: Add initial version of meson based build system
- e6927270cd18 16.0 cited
On Tue, Mar 26, 2024 at 2:27 PM Bharath Rupireddy <bharath.rupireddyforpostgres@gmail.com> wrote: > > > > > 1) > > Commti msg: > > > > ensures the value is set to current timestamp during the > > shutdown to help correctly interpret the time if the standby gets > > promoted without a restart. > > > > shutdown --> shutdown of slot sync worker (as it was not clear if it > > is instance shutdown or something else) > > Changed it to "shutdown of slot sync machinery" to be consistent with > the comments. Thanks for addressing the comments. Just to give more clarity here (so that you take a informed decision), I am not sure if we actually shut down slot-sync machinery. We only shot down slot sync worker. Slot-sync machinery can still be used using 'pg_sync_replication_slots' SQL function. I can easily reproduce the scenario where SQL function and reset_synced_slots_info() are going in parallel where the latter hits 'Assert(s->active_pid == 0)' due to the fact that parallel SQL sync function is active on that slot. thanks Shveta