Cc: Masahiko Sawada <sawada.mshk@gmail.com>, "Zhijie Hou (Fujitsu)" <houzj.fnst@fujitsu.com>, "Drouvot, Bertrand" <bertranddrouvot.pg@gmail.com>, Peter Smith <smithpb2250@gmail.com>, Nisha Moond <nisha.moond412@gmail.com>, "Hayato Kuroda (Fujitsu)" <kuroda.hayato@fujitsu.com>, Bharath Rupireddy <bharath.rupireddyforpostgres@gmail.com>, Peter Eisentraut <peter.eisentraut@enterprisedb.com>, Bruce Momjian <bruce@momjian.us>, Ashutosh Sharma <ashu.coek88@gmail.com>, Andres Freund <andres@anarazel.de>, pgsql-hackers <pgsql-hackers@postgresql.org>, Ajin Cherian <itsajin@gmail.com>, Alvaro Herrera <alvherre@alvh.no-ip.org>, shveta malik <shveta.malik@gmail.com>
Date: 2023-12-28T10:33:09Z
Lists: pgsql-hackers

Attachments

On Wed, Dec 27, 2023 at 4:13 PM Amit Kapila <amit.kapila16@gmail.com> wrote:
>
> On Wed, Dec 27, 2023 at 11:36 AM Masahiko Sawada <sawada.mshk@gmail.com> wrote:
> >
> > On Tue, Dec 26, 2023 at 9:27 PM shveta malik <shveta.malik@gmail.com> wrote:
> > >
> > > I would like to revisit the current dependency of slotsync worker on
> > > dbname used in 002 patch. Currently we accept dbname in
> > > primary_conninfo and thus the user has to make sure to provide one (by
> > > manually altering it) even in case of a conf file auto-generated by
> > > "pg_basebackup -R".
> > > Thus I would like to discuss if there are better ways to do it.
> > > Complete background is as follow:
> > >
> > > We need dbname for 2 purposes:
> > >
> > > 1) to connect to remote db in order to run SELECT queries to fetch the
> > > info needed by slotsync worker.
> > > 2) to make connection in slot-sync worker itself in order to be able
> > > to use libpq APIs for 1)
> > >
> > > We run 3 kind of select queries in slot-sync worker currently:
> > >
> > > a) To fetch all failover slots (logical slots) info at once in
> > > synchronize_slots().
> > > b) To fetch a particular slot info during
> > > wait_for_primary_slot_catchup() logic (logical slot).
> > > c) To validate primary slot (physical one) and also to distinguish
> > > between standby and cascading standby by running pg_is_in_recovery().
> > >
> > >  1) One approach to avoid dependency on dbname is using commands
> > > instead of SELECT.  This will need implementing LIST_SLOTS command for
> > > a), and for b) we can use LIST_SLOTS and fetch everything (even though
> > > it is not needed) or have LIST_SLOTS with a filter on slot-name or
> > > extend READ_REPLICATION_SLOT,  and for c) we can have some other
> > > command to get pg_is_in_recovery() info. But, I feel by relying on
> > > commands we will be making the extension of the slot-sync feature
> > > difficult. In future, if there is some more requirement to fetch any
> > > other info,
> > > then there too we have to implement a command. I am not sure if it is
> > > good and extensible approach.
> > >
> > > 2) Another way to avoid asking for a dbname in primary_conninfo is to
> > > use the default dbname internally. This brings us to two questions:
> > > 'How' and 'Which default db'?
> > >
> > > 2.1) To answer 'How':
> > > Using default dbname is simpler for the purpose of slot-sync worker
> > > having its own db-connection, but is a little tricky for the purpose
> > > of connection to remote_db. This is because we have to inject this
> > > dbname internally in our connection-info.
> > >
> > > 2.1.1) Say we use primary_conninfo (i.e. original one w/o dbname),
> > > then currently it could have 2 formats:
> > >
> > > a) The simple "=" format for key-value pairs, example:
> > > 'user=replication host=127.0.0.1 port=5433 dbname=postgres'.
> > > b) URI format, example:
> > > postgresql://other@localhost/otherdb?connect_timeout=10&application_name=myapp
> > >
> > > We can distinguish between the 2 formats using 'uri_prefix_length' but
> > > injecting the dbname part will be messy specially for URI format.  If
> > > we want to do it w/o injecting and only by changing libpq interfaces
> > > to accept dbname separately apart from conninfo, then there is no
> > > current simpler way available. It will need a good amount of changes
> > > in libpq.
> > >
> > > 2.1.2) Another way is to not rely on primary_conninfo directly but
> > > rely on 'WalRcv->conninfo' in order to connect to remote_db. This is
> > > because the latter is never URI format, it is some parsed format and
> > > appending may work. As an example, primary_conninfo =
> > > 'postgresql://replication@localhost:5433', WalRcv->conninfo loaded
> > > internally is:
> > > "user=replication passfile=/home/shveta/.pgpass channel_binding=prefer
> > > dbname=replication host=localhost port=5433
> > > fallback_application_name=walreceiver sslmode=prefer sslcompression=0
> > > sslcertmode=allow sslsni=1 ssl_min_protocol_version=TLSv1.2
> > > gssencmode=disable krbsrvname=postgres gssdelegation=0
> > > target_session_attrs=any load_balance_hosts=disable", '\000'
> > >
> > > So we can try appending our default dbname to this. But all the
> > > defaults loaded in WalRcv->conninfo need some careful analysis to
> > > figure out if they work for slot-sync worker case.
> > >
> > > 2.2) Now coming to 'Which default db':
> > >
> > > 2.2.1) If we use 'template1' as default db, it may block 'create db'
> > > operations on primary for the time when the slot-sync worker is
> > > connected to remote using this dbname. Example:
> > >
> > > postgres=# create database newdb1;
> > > ERROR:  source database "template1" is being accessed by other users
> > > DETAIL:  There is 1 other session using the database.
> > >
> > > 2.2.2) If we use 'postgres' as default db, there are chances that it
> > > can be dropped as unlike 'template1', it is allowed to be dropped by
> > > user, and if slotsync worker is connected to it, user may see:
> > > newdb1=# drop database postgres;
> > > ERROR:  database "postgres" is being accessed by other users
> > > DETAIL:  There is 1 other session using the database.
> > >
> > > But once the slot-sync worker or standby goes down, user can always
> > > drop this and next time slot-sync worker may not be able to come up.
> > >
> >
> > Other random ideas for discussion are:
> >
> > 3) The slotsync worker uses primary_conninfo but also uses a new GUC
> > parameter, say slot_sync_dbname, to specify the database to connect.
> > The slot_sync_dbname overwrites the dbname if primary_conninfo also
> > specifies it. If both don't have a dbname, raise an error.
> >
>
> Would the users prefer to provide a value for a separate GUC instead
> of changing primary_conninfo? It is possible that we can have some
> users prefer to use one GUC and others prefer a separate GUC but we
> should add a new GUC if we are sure that is what users would prefer.
> Also, even if have to consider this option, I think we can easily
> later add a new GUC to provide a dbname in addition to having the
> provision of giving it in primary_conninfo.
>
> Also, I think having a separate GUC for dbanme has some complexity in
> terms of appending the dbname to primary_conninfo as pointed out by
> Shveta.
>
> > 4) The slotsync worker uses a new GUC parameter, say
> > slot_sync_conninfo, to specify the connection string to the primary
> > aside from primary_conninfo. And pg_basebackup -R generates
> > slot_sync_conninfo as well if required (new option required).
> >
>
> Yeah, this is worth considering but won't slot_sync_conninfo be mostly
> a duplicate of primary_conninfo apart from dbname? I am not sure if
> the benefit outweighs the disadvantage of having mostly similar
> information in two GUCs.
>
> --
> With Regards,
> Amit Kapila.


PFA v55. It has fixes for 2 CFBot failures seen on v53 and 1 CFBot
failure seen on v54.

patch002:
1) In 32-bit env, a Datum for int64 is treated  as a pointer, and thus
below leads to NULL pointer access if the concerned attribute is NULL.
Corrected it now.
DatumGetLSN(slot_getattr(tupslot, 3, &isnull));

2)During slot-creation on standby it is possible to get NULL
confirmed_lsn from primary even for a valid slot with valid
restart_lsn. This may happen when a slot is just created on primary
with valid restart_lsn and slot-sync worker has fetched it before
primary could set valid confirmed_lsn. And thus along with
remote_slot's restart_lsn to catch up, we also need to check for
non-null confirmed_lsn of remote_slot.

patch003:
3) Another intermittent failure was due to an unstable test added in
050_standby_failover_slots_sync.pl. It has now been removed.  The
other tests already have the coverage which the problematic test was
trying to achieve. Thank You Hou-san for working on this.

thanks
Shveta

Commits

  1. Doc: Add the new section "Logical Replication Failover".

  2. Fix the review comments and a bug in the slot sync code.

  3. Fix a test in failover slots regression test.

  4. Fix the intermittent buildfarm failures in 040_standby_failover_slots_sync.

  5. Split XLogCtl->LogwrtResult into separate struct members

  6. Ensure that the sync slots reach a consistent state after promotion without losing data.

  7. Introduce a new GUC 'standby_slot_names'.

  8. Fix BF failure introduced by commit b3f6b14cf4.

  9. Fixups for commit 93db6cbda0.

  10. Fix BF failure in commit 93db6cbda0.

  11. Add a new slot sync worker to synchronize logical slots.

  12. Improve ERROR/LOG messages added by commits ddd5f4f54a and 7a424ece48.

  13. Disable autovacuum on primary in 040_standby_failover_slots_sync test.

  14. Fix the incorrect format specifier used in commit 7a424ece48.

  15. Change the LOG level in 040_standby_failover_slots_sync.pl to DEBUG2.

  16. Add more LOG and DEBUG messages for slot synchronization.

  17. Another try to fix BF failure introduced in commit ddd5f4f54a.

  18. Fix BF introduced in commit ddd5f4f54a.

  19. Add a slot synchronization function.

  20. Clean-ups for 776621a5e4 and 7329240437.

  21. Enhance libpqrcv APIs to support slot synchronization.

  22. Add a failover option to subscriptions.

  23. Allow setting failover property in the replication command.

  24. Allow to enable failover property for replication slots via SQL API.

  25. Add macros for looping through a List without a ListCell.

  26. Track conflict_reason in pg_replication_slots.

  27. Allow upgrades to preserve the full subscription's state.

  28. Add support for incremental backup.

  29. Simplify some logic in CreateReplicationSlot()

  30. Fix uninitialized access to InitialRunningXacts during decoding after ERROR.

  31. Flexible options for CREATE_REPLICATION_SLOT.

  32. Empty search_path in logical replication apply worker and walsender.

  33. Fix oldest xmin and LSN computation across repslots after advancing

  34. Require C99 (and thus MSCV 2013 upwards).