error message is not proper for analyze on standby.
Tomonari Katsumata <t.katsumata1122@gmail.com>
From: Tomonari Katsumata <t.katsumata1122@gmail.com>
To: pgsql-hackers@postgresql.org
Date: 2012-10-06T03:16:38Z
Lists: pgsql-hackers
Attachments
- analyze_message_on_hotstandby.patch (application/octet-stream) patch
Hi, I work with streaming replication and hot standby. and I noticed that error message is not proper when I issue ANALYZE command to standby. [before] ======================================================== -bash-3.2$ psql -c "analyze" ERROR: cannot execute VACUUM during recovery STATEMENT: analyze ERROR: cannot execute VACUUM during recovery ======================================================== ANALYZE command is not VACUUM command. I attached a patch revised the message. [after] ======================================================== -bash-3.2$ psql -c "analyze" ERROR: cannot execute ANALYZE during recovery STATEMENT: analyze ERROR: cannot execute ANALYZE during recovery ======================================================== this is not big problem, but error message should be report actual thing. please check it. regards, ------------- Tomonari Katsumata