Re: Introduce XID age and inactive timeout based replication slot invalidation
Nisha Moond <nisha.moond412@gmail.com>
Commits
GET /api/v1/messages/:b64id/commits
the thread's linked commits as JSON, with link sources.
API reference →
-
Add a test for commit ac0e33136a using the injection point.
- 8a695d7998be 18.0 landed
-
Invalidate inactive replication slots.
- ac0e33136abc 18.0 landed
-
Fix incorrect slot type in BuildTupleHashTableExt
- d96d1d5152f3 18.0 cited
-
Allow synced slots to have their inactive_since.
- 6f132ed693b6 17.0 landed
-
Change last_inactive_time to inactive_since in pg_replication_slots.
- 6d49c8d4b4f4 17.0 landed
-
Track last_inactive_time in pg_replication_slots.
- a11f330b5584 17.0 landed
-
Track invalidation_reason in pg_replication_slots.
- 6ae701b4378d 17.0 landed
-
Add option force_initdb to PostgreSQL::Test::Cluster:init()
- ff9e1e764fcc 17.0 cited
-
Add a failover option to subscriptions.
- 776621a5e479 17.0 cited
-
Allow setting failover property in the replication command.
- 73292404370c 17.0 cited
-
Allow to enable failover property for replication slots via SQL API.
- c393308b69d2 17.0 cited
-
Track conflict_reason in pg_replication_slots.
- 007693f2a3ac 17.0 cited
-
Log messages for replication slot acquisition and release.
- 7c3fb505b14e 17.0 cited
-
Remove vacuum_defer_cleanup_age
- 1118cd37eb61 16.0 cited
-
Fix corruption due to vacuum_defer_cleanup_age underflowing 64bit xids
- be504a3e974d 16.0 cited
-
meson: Add initial version of meson based build system
- e6927270cd18 16.0 cited
On Wed, Sep 18, 2024 at 3:31 PM shveta malik <shveta.malik@gmail.com> wrote: > > On Wed, Sep 18, 2024 at 2:49 PM shveta malik <shveta.malik@gmail.com> wrote: > > > > > > Please find the attached v46 patch having changes for the above review > > > > comments and your test review comments and Shveta's review comments. > > > > > > When the synced slot is marked as 'inactive_timeout' invalidated on > hot standby due to invalidation of publisher 's failover slot, the > former starts showing NULL' inactive_since'. Is this intentional > behaviour? I feel inactive_since should be non-NULL here too? > Thoughts? > > physical standby: > postgres=# select slot_name, inactive_since, invalidation_reason, > failover, synced from pg_replication_slots; > slot_name | inactive_since | > invalidation_reason | failover | synced > -------------+----------------------------------+---------------------+----------+-------- > sub2 | 2024-09-18 15:20:04.364998+05:30 | | t | t > sub3 | 2024-09-18 15:20:04.364953+05:30 | | t | t > > After sync of invalidation_reason: > > slot_name | inactive_since | invalidation_reason | > failover | synced > -------------+----------------------------------+---------------------+----------+-------- > sub2 | | inactive_timeout | t | t > sub3 | | inactive_timeout | t | t > > For synced slots on the standby, inactive_since indicates the last synchronization time rather than the time the slot became inactive (see doc - https://www.postgresql.org/docs/devel/view-pg-replication-slots.html). In the reported case above, once a synced slot is invalidated we don't even keep the last synchronization time for it. This is because when a synced slot on the standby is marked invalid, inactive_since is reset to NULL each time the slot-sync worker acquires a lock on it. This lock acquisition before checking invalidation is done to avoid certain race conditions and will activate the slot temporarily, resetting inactive_since. Later, the slot-sync worker updates inactive_since for all synced slots to the current synchronization time. However, for invalid slots, this update is skipped, as per the patch’s design. If we want to preserve the inactive_since value for the invalid synced slots on standby, we need to clarify the time it should display. Here are three possible approaches: 1) Copy the primary's inactive_since upon invalidation: When a slot becomes invalid on the primary, the slot-sync worker could copy the primary slot’s inactive_since to the standby slot and retain it, by preventing future updates on the standby. 2) Use the current time of standby when the synced slot is marked invalid for the first time and do not update it in subsequent sync cycles if the slot is invalid. Approach (2) seems more reasonable to me, however, Both 1) & 2) approaches contradicts the purpose of inactive_since, as it no longer represents either the true "last sync time" or the "time slot became inactive" because the slot-sync worker acquires locks periodically for syncing, and keeps activating the slot. 3) Continuously update inactive_since for invalid synced slots as well: Treat invalid synced slots like valid ones by updating inactive_since with each sync cycle. This way, we can keep the "last sync time" in the inactive_since. However, this could confuse users when "invalidation_reason=inactive_timeout" is set for a synced slot on standby but inactive_since would reflect sync time rather than the time slot became inactive. IIUC, on the primary, when invalidation_reason=inactive_timeout for a slot, the inactive_since represents the actual time the slot became inactive before getting invalidated, unless the primary is restarted. Thoughts? -- Thanks, Nisha