Re: Introduce XID age and inactive timeout based replication slot invalidation
Nisha Moond <nisha.moond412@gmail.com>
Commits
GET /api/v1/messages/:b64id/commits
the thread's linked commits as JSON, with link sources.
API reference →
-
Add a test for commit ac0e33136a using the injection point.
- 8a695d7998be 18.0 landed
-
Invalidate inactive replication slots.
- ac0e33136abc 18.0 landed
-
Fix incorrect slot type in BuildTupleHashTableExt
- d96d1d5152f3 18.0 cited
-
Allow synced slots to have their inactive_since.
- 6f132ed693b6 17.0 landed
-
Change last_inactive_time to inactive_since in pg_replication_slots.
- 6d49c8d4b4f4 17.0 landed
-
Track last_inactive_time in pg_replication_slots.
- a11f330b5584 17.0 landed
-
Track invalidation_reason in pg_replication_slots.
- 6ae701b4378d 17.0 landed
-
Add option force_initdb to PostgreSQL::Test::Cluster:init()
- ff9e1e764fcc 17.0 cited
-
Add a failover option to subscriptions.
- 776621a5e479 17.0 cited
-
Allow setting failover property in the replication command.
- 73292404370c 17.0 cited
-
Allow to enable failover property for replication slots via SQL API.
- c393308b69d2 17.0 cited
-
Track conflict_reason in pg_replication_slots.
- 007693f2a3ac 17.0 cited
-
Log messages for replication slot acquisition and release.
- 7c3fb505b14e 17.0 cited
-
Remove vacuum_defer_cleanup_age
- 1118cd37eb61 16.0 cited
-
Fix corruption due to vacuum_defer_cleanup_age underflowing 64bit xids
- be504a3e974d 16.0 cited
-
meson: Add initial version of meson based build system
- e6927270cd18 16.0 cited
Attachments
- v50-0001-Add-error-handling-while-acquiring-a-replication.patch (application/octet-stream) patch v50-0001
- v50-0002-Introduce-inactive_timeout-based-replication-slo.patch (application/octet-stream) patch v50-0002
On Wed, Nov 20, 2024 at 1:29 PM vignesh C <vignesh21@gmail.com> wrote: > > On Tue, 19 Nov 2024 at 12:43, Nisha Moond <nisha.moond412@gmail.com> wrote: > > > > Attached is the v49 patch set: > > - Fixed the bug reported in [1]. > > - Addressed comments in [2] and [3]. > > > > I've split the patch into two, implementing the suggested idea in > > comment #5 of [2] separately in 001: > > > > Patch-001: Adds additional error reports (for all invalidation types) > > in ReplicationSlotAcquire() for invalid slots when error_if_invalid = > > true. > > Patch-002: The original patch with comments addressed. > > This Assert can fail: > Attached v50 patch-set addressing review comments in [1] and [2]. Regarding the assert issue reported in [2]: - For temporary replication slots, the current session's pid serves as the active_pid for the slot, which is expected behavior. - Therefore, the ASSERT has been removed in v50. Now, if a temporary slot qualifies for a timeout invalidation, the holding process will be terminated, and the slot will be invalidated. [1] https://www.postgresql.org/message-id/CALDaNm2UUTfJczjR-rEQwKgmx%3DiFnuMnR1cXv7ccB%2BO9P15mYg%40mail.gmail.com [2] https://www.postgresql.org/message-id/CALDaNm0g86wD2%3DbQdFOy0smsP0MZWyz0CUqXej%3DQi-hCEeqkag%40mail.gmail.com -- Thanks, Nisha