Re: Introduce XID age and inactive timeout based replication slot invalidation

Nisha Moond <nisha.moond412@gmail.com>

From: Nisha Moond <nisha.moond412@gmail.com>
To: Amit Kapila <amit.kapila16@gmail.com>
Cc: Peter Smith <smithpb2250@gmail.com>, vignesh C <vignesh21@gmail.com>, "Hayato Kuroda (Fujitsu)" <kuroda.hayato@fujitsu.com>, shveta malik <shveta.malik@gmail.com>, Bharath Rupireddy <bharath.rupireddyforpostgres@gmail.com>, Ajin Cherian <itsajin@gmail.com>, Bertrand Drouvot <bertranddrouvot.pg@gmail.com>, Masahiko Sawada <sawada.mshk@gmail.com>, Nathan Bossart <nathandbossart@gmail.com>, PostgreSQL Hackers <pgsql-hackers@lists.postgresql.org>
Date: 2024-12-24T11:36:55Z
Lists: pgsql-hackers

Commits

Same data as JSON: GET /api/v1/messages/:b64id/commits the thread's linked commits as JSON, with link sources. API reference →
  1. Add a test for commit ac0e33136a using the injection point.

  2. Invalidate inactive replication slots.

  3. Fix incorrect slot type in BuildTupleHashTableExt

  4. Allow synced slots to have their inactive_since.

  5. Change last_inactive_time to inactive_since in pg_replication_slots.

  6. Track last_inactive_time in pg_replication_slots.

  7. Track invalidation_reason in pg_replication_slots.

  8. Add option force_initdb to PostgreSQL::Test::Cluster:init()

  9. Add a failover option to subscriptions.

  10. Allow setting failover property in the replication command.

  11. Allow to enable failover property for replication slots via SQL API.

  12. Track conflict_reason in pg_replication_slots.

  13. Log messages for replication slot acquisition and release.

  14. Remove vacuum_defer_cleanup_age

  15. Fix corruption due to vacuum_defer_cleanup_age underflowing 64bit xids

  16. meson: Add initial version of meson based build system

Attachments

On Fri, Dec 20, 2024 at 3:12 PM Amit Kapila <amit.kapila16@gmail.com> wrote:

> On Mon, Dec 16, 2024 at 4:10 PM Nisha Moond <nisha.moond412@gmail.com>
> wrote:
> >
> > Here is the v56 patch set with the above comments incorporated.
> >
>
> Review comments:
> ===============
> 1.
> + {
> + {"idle_replication_slot_timeout", PGC_SIGHUP, REPLICATION_SENDING,
> + gettext_noop("Sets the duration a replication slot can remain idle
> before "
> + "it is invalidated."),
> + NULL,
> + GUC_UNIT_MS
> + },
> + &idle_replication_slot_timeout_ms,
>
> I think users are going to keep idele_slot timeout at least in hours.
> So, millisecond seems the wrong choice to me. I suggest to keep the
> units in minutes. I understand that writing a test would be
> challenging as spending a minute or more on one test is not advisable.
> But I don't see any test testing the other GUCs that are in minutes
> (wal_summary_keep_time and log_rotation_age). The default value should
> be one day.
>

+1
- Changed the GUC unit to "minute".

Regarding the tests, we have two potential options:
 1) Introduce an additional "debug_xx" GUC parameter with units of seconds
or milliseconds, only for testing purposes.
 2) Skip writing tests for this, similar to other GUCs with units in
minutes.

IMO, adding an additional GUC just for testing may not be worthwhile. It's
reasonable to proceed without the test.

Thoughts?

The attached v57 patch-set addresses all the comments. I have kept the test
case in the patch for now, it takes 2-3 minutes to complete.

--
Thanks,