Re: Introduce XID age and inactive timeout based replication slot invalidation
Nisha Moond <nisha.moond412@gmail.com>
Commits
GET /api/v1/messages/:b64id/commits
the thread's linked commits as JSON, with link sources.
API reference →
-
Add a test for commit ac0e33136a using the injection point.
- 8a695d7998be 18.0 landed
-
Invalidate inactive replication slots.
- ac0e33136abc 18.0 landed
-
Fix incorrect slot type in BuildTupleHashTableExt
- d96d1d5152f3 18.0 cited
-
Allow synced slots to have their inactive_since.
- 6f132ed693b6 17.0 landed
-
Change last_inactive_time to inactive_since in pg_replication_slots.
- 6d49c8d4b4f4 17.0 landed
-
Track last_inactive_time in pg_replication_slots.
- a11f330b5584 17.0 landed
-
Track invalidation_reason in pg_replication_slots.
- 6ae701b4378d 17.0 landed
-
Add option force_initdb to PostgreSQL::Test::Cluster:init()
- ff9e1e764fcc 17.0 cited
-
Add a failover option to subscriptions.
- 776621a5e479 17.0 cited
-
Allow setting failover property in the replication command.
- 73292404370c 17.0 cited
-
Allow to enable failover property for replication slots via SQL API.
- c393308b69d2 17.0 cited
-
Track conflict_reason in pg_replication_slots.
- 007693f2a3ac 17.0 cited
-
Log messages for replication slot acquisition and release.
- 7c3fb505b14e 17.0 cited
-
Remove vacuum_defer_cleanup_age
- 1118cd37eb61 16.0 cited
-
Fix corruption due to vacuum_defer_cleanup_age underflowing 64bit xids
- be504a3e974d 16.0 cited
-
meson: Add initial version of meson based build system
- e6927270cd18 16.0 cited
Attachments
- v57-0001-Enhance-replication-slot-error-handling-slot-inv.patch (application/octet-stream) patch v57-0001
- v57-0002-Introduce-inactive_timeout-based-replication-slo.patch (application/octet-stream) patch v57-0002
On Fri, Dec 20, 2024 at 3:12 PM Amit Kapila <amit.kapila16@gmail.com> wrote:
> On Mon, Dec 16, 2024 at 4:10 PM Nisha Moond <nisha.moond412@gmail.com>
> wrote:
> >
> > Here is the v56 patch set with the above comments incorporated.
> >
>
> Review comments:
> ===============
> 1.
> + {
> + {"idle_replication_slot_timeout", PGC_SIGHUP, REPLICATION_SENDING,
> + gettext_noop("Sets the duration a replication slot can remain idle
> before "
> + "it is invalidated."),
> + NULL,
> + GUC_UNIT_MS
> + },
> + &idle_replication_slot_timeout_ms,
>
> I think users are going to keep idele_slot timeout at least in hours.
> So, millisecond seems the wrong choice to me. I suggest to keep the
> units in minutes. I understand that writing a test would be
> challenging as spending a minute or more on one test is not advisable.
> But I don't see any test testing the other GUCs that are in minutes
> (wal_summary_keep_time and log_rotation_age). The default value should
> be one day.
>
+1
- Changed the GUC unit to "minute".
Regarding the tests, we have two potential options:
1) Introduce an additional "debug_xx" GUC parameter with units of seconds
or milliseconds, only for testing purposes.
2) Skip writing tests for this, similar to other GUCs with units in
minutes.
IMO, adding an additional GUC just for testing may not be worthwhile. It's
reasonable to proceed without the test.
Thoughts?
The attached v57 patch-set addresses all the comments. I have kept the test
case in the patch for now, it takes 2-3 minutes to complete.
--
Thanks,