Re: Synchronizing slots from primary to standby
Amit Kapila <amit.kapila16@gmail.com>
On Fri, Feb 2, 2024 at 6:46 AM Masahiko Sawada <sawada.mshk@gmail.com> wrote: > > On Thu, Feb 1, 2024 at 12:51 PM Amit Kapila <amit.kapila16@gmail.com> wrote: > > > > > > > BTW I've tested the following switch/fail-back scenario but it seems > > > not to work fine. Am I missing something? > > > > > > Setup: > > > node1 is the primary, node2 is the physical standby for node1, and > > > node3 is the subscriber connecting to node1. > > > > > > Steps: > > > 1. [node1]: create a table and a publication for the table. > > > 2. [node2]: set enable_syncslot = on and start (to receive WALs from node1). > > > 3. [node3]: create a subscription with failover = true for the publication. > > > 4. [node2]: promote to the new standby. > > > 5. [node3]: alter subscription to connect the new primary, node2. > > > 6. [node1]: stop, set enable_syncslot = on (and other required > > > parameters), then start as a new standby. > > > > > > Then I got the error "exiting from slot synchronization because same > > > name slot "test_sub" already exists on the standby". > > > > > > The logical replication slot that was created on the old primary > > > (node1) has been synchronized to the old standby (node2). Therefore on > > > node2, the slot's "synced" field is true. However, once node1 starts > > > as the new standby with slot synchronization, the slotsync worker > > > cannot synchronize the slot because the slot's "synced" field on the > > > primary is false. > > > > > > > Yeah, we avoided doing anything in this case because the user could > > have manually created another slot with the same name on standby. > > Unlike WAL slots can be modified on standby as we allow decoding on > > standby, so we can't allow to overwrite the existing slots. We won't > > be able to distinguish whether the existing slot was a slot that the > > user wants to sync with primary or a slot created on standby to > > perform decoding. I think in this case user first needs to drop the > > slot on new standby. > > Yes, but if we do a switch-back further (i.e. in above case, node1 > backs to the primary again and node becomes the standby again), the > user doesn't need to remove failover slots since they are already > marked as "synced". But, I think in this case node-2's timeline will be ahead of node-1, so will we be able to make node-2 follow node-1 again without any additional steps? One thing is not clear to me after promotion the timeline changes in WAL, so the locations in slots will be as per new timelines, after that will it be safe to sync slots from the new primary to old-primary? In general, I think after failover, we recommend running pg_rewind if the old primary has to follow the new primary to account for divergence in WAL. So, not sure we can safely start syncing slots in old-primary from new-primary, consider that in the new primary, the same name slot may have dropped/re-created multiple times. We can probably reset all the fields of the existing slot the first time syncing for an existing slot or do something like that but I think it would be better to just re-create the slot. > I wonder if we could do something automatically to > reduce the user's operation. One possibility is that we forcefully drop/re-create the slot or directly overwrite the slot contents but that would probably be better done via some GUC or slot-level parameter. I feel we should leave this for another day, for the first version, we can document that an error will occur if the same name slots on standby exist, so users need to ensure that there shouldn't be an existing same name slots on standby before sync. -- With Regards, Amit Kapila.
Commits
-
Doc: Add the new section "Logical Replication Failover".
- b560a98a17ae 17.0 landed
-
Fix the review comments and a bug in the slot sync code.
- 3741f2a09d52 17.0 landed
-
Fix a test in failover slots regression test.
- 7e85d1c75f29 17.0 landed
-
Fix the intermittent buildfarm failures in 040_standby_failover_slots_sync.
- 6f3d8d5e7cc2 17.0 landed
-
Split XLogCtl->LogwrtResult into separate struct members
- c9920a9068ea 17.0 cited
-
Ensure that the sync slots reach a consistent state after promotion without losing data.
- 2ec005b4e297 17.0 landed
-
Introduce a new GUC 'standby_slot_names'.
- bf279ddd1c28 17.0 landed
-
Fix BF failure introduced by commit b3f6b14cf4.
- def0ce337068 17.0 landed
-
Fixups for commit 93db6cbda0.
- b3f6b14cf48f 17.0 landed
-
Fix BF failure in commit 93db6cbda0.
- d13ff82319cc 17.0 landed
-
Add a new slot sync worker to synchronize logical slots.
- 93db6cbda037 17.0 landed
-
Improve ERROR/LOG messages added by commits ddd5f4f54a and 7a424ece48.
- 801792e528d6 17.0 landed
-
Disable autovacuum on primary in 040_standby_failover_slots_sync test.
- b7bdade6a42f 17.0 landed
-
Fix the incorrect format specifier used in commit 7a424ece48.
- b987be39c3c7 17.0 landed
-
Change the LOG level in 040_standby_failover_slots_sync.pl to DEBUG2.
- d9e225f275b7 17.0 landed
-
Add more LOG and DEBUG messages for slot synchronization.
- 7a424ece4828 17.0 landed
-
Another try to fix BF failure introduced in commit ddd5f4f54a.
- 9bc1eee988c3 17.0 landed
-
Fix BF introduced in commit ddd5f4f54a.
- bd8fc1677b88 17.0 landed
-
Add a slot synchronization function.
- ddd5f4f54a02 17.0 landed
-
Clean-ups for 776621a5e4 and 7329240437.
- 22f7e61a6330 17.0 landed
-
Enhance libpqrcv APIs to support slot synchronization.
- dafbfed9efbe 17.0 landed
-
Add a failover option to subscriptions.
- 776621a5e479 17.0 landed
-
Allow setting failover property in the replication command.
- 73292404370c 17.0 landed
-
Allow to enable failover property for replication slots via SQL API.
- c393308b69d2 17.0 landed
-
Add macros for looping through a List without a ListCell.
- 14dd0f27d7cd 17.0 cited
-
Track conflict_reason in pg_replication_slots.
- 007693f2a3ac 17.0 cited
-
Allow upgrades to preserve the full subscription's state.
- 9a17be1e244a 17.0 cited
-
Add support for incremental backup.
- dc212340058b 17.0 cited
-
Simplify some logic in CreateReplicationSlot()
- e83aa9f92fdd 17.0 cited
-
Fix uninitialized access to InitialRunningXacts during decoding after ERROR.
- c7256e6564fa 15.5 cited
-
Flexible options for CREATE_REPLICATION_SLOT.
- 0266e98c6b86 15.0 cited
-
Empty search_path in logical replication apply worker and walsender.
- 11da97024abb 14.0 cited
-
Fix oldest xmin and LSN computation across repslots after advancing
- b48df818dcbd 14.0 cited
-
Require C99 (and thus MSCV 2013 upwards).
- d9dd406fe281 12.0 cited