Re: Synchronizing slots from primary to standby

Amit Kapila <amit.kapila16@gmail.com>

From: Amit Kapila <amit.kapila16@gmail.com>
To: Peter Smith <smithpb2250@gmail.com>
Cc: "Zhijie Hou (Fujitsu)" <houzj.fnst@fujitsu.com>, shveta malik <shveta.malik@gmail.com>, "Drouvot, Bertrand" <bertranddrouvot.pg@gmail.com>, Nisha Moond <nisha.moond412@gmail.com>, "Hayato Kuroda (Fujitsu)" <kuroda.hayato@fujitsu.com>, Bharath Rupireddy <bharath.rupireddyforpostgres@gmail.com>, Peter Eisentraut <peter.eisentraut@enterprisedb.com>, Bruce Momjian <bruce@momjian.us>, Ashutosh Sharma <ashu.coek88@gmail.com>, Andres Freund <andres@anarazel.de>, pgsql-hackers <pgsql-hackers@postgresql.org>, Ajin Cherian <itsajin@gmail.com>, Alvaro Herrera <alvherre@alvh.no-ip.org>
Date: 2023-12-11T08:35:30Z
Lists: pgsql-hackers
On Mon, Dec 11, 2023 at 1:02 PM Peter Smith <smithpb2250@gmail.com> wrote:
>
> Here are some review comments for v44-0001
>
> ~~~
>
> 3. assign_standby_slot_names
>
> + if (!SplitIdentifierString(standby_slot_names_cpy, ',', &standby_slots))
> + {
> + /* This should not happen if GUC checked check_standby_slot_names. */
> + elog(ERROR, "list syntax is invalid");
> + }
>
> This error here and in validate_standby_slots() are different --
> "list" versus "List".
>

Note here elog(ERROR,.. is used and in the other place it is part of
the detail message. I have suggested in my previous review to make
them the same but I overlooked the difference, so I think we should
change the message to "invalid list syntax" as it was there
previously.

> ======
> src/backend/replication/walsender.c
>
>
> 4. WalSndFilterStandbySlots
>
>
> + foreach(lc, standby_slots_cpy)
> + {
> + char    *name = lfirst(lc);
> + XLogRecPtr restart_lsn = InvalidXLogRecPtr;
> + bool invalidated = false;
> + char    *warningfmt = NULL;
> + ReplicationSlot *slot;
> +
> + slot = SearchNamedReplicationSlot(name, true);
> +
> + if (slot && SlotIsPhysical(slot))
> + {
> + SpinLockAcquire(&slot->mutex);
> + restart_lsn = slot->data.restart_lsn;
> + invalidated = slot->data.invalidated != RS_INVAL_NONE;
> + SpinLockRelease(&slot->mutex);
> + }
> +
> + /* Continue if the current slot hasn't caught up. */
> + if (!invalidated && !XLogRecPtrIsInvalid(restart_lsn) &&
> + restart_lsn < wait_for_lsn)
> + {
> + /* Log warning if no active_pid for this physical slot */
> + if (slot->active_pid == 0)
> + ereport(WARNING,
> + errmsg("replication slot \"%s\" specified in parameter \"%s\" does
> not have active_pid",
> +    name, "standby_slot_names"),
> + errdetail("Logical replication is waiting on the "
> +   "standby associated with \"%s\"", name),
> + errhint("Consider starting standby associated with "
> + "\"%s\" or amend standby_slot_names", name));
> +
> + continue;
> + }
> + else if (!slot)
> + {
> + /*
> + * It may happen that the slot specified in standby_slot_names GUC
> + * value is dropped, so let's skip over it.
> + */
> + warningfmt = _("replication slot \"%s\" specified in parameter
> \"%s\" does not exist, ignoring");
> + }
> + else if (SlotIsLogical(slot))
> + {
> + /*
> + * If a logical slot name is provided in standby_slot_names, issue
> + * a WARNING and skip it. Although logical slots are disallowed in
> + * the GUC check_hook(validate_standby_slots), it is still
> + * possible for a user to drop an existing physical slot and
> + * recreate a logical slot with the same name. Since it is
> + * harmless, a WARNING should be enough, no need to error-out.
> + */
> + warningfmt = _("cannot have logical replication slot \"%s\" in
> parameter \"%s\", ignoring");
> + }
> + else if (XLogRecPtrIsInvalid(restart_lsn) || invalidated)
> + {
> + /*
> + * Specified physical slot may have been invalidated, so there is no point
> + * in waiting for it.
> + */
> + warningfmt = _("physical slot \"%s\" specified in parameter \"%s\"
> has been invalidated, ignoring");
> + }
> + else
> + {
> + Assert(restart_lsn >= wait_for_lsn);
> + }
>
> This if/else chain seems structured awkwardly. IMO it would be tidier
> to eliminate the NULL slot and IsLogicalSlot up-front, which would
> also simplify some of the subsequent conditions
>
> SUGGESTION
>
> slot = SearchNamedReplicationSlot(name, true);
>
> if (!slot)
> {
> ...
> }
> else if (SlotIsLogical(slot))
> {
> ...
> }
> else
> {
>   Assert(SlotIsPhysical(slot))
>
>   SpinLockAcquire(&slot->mutex);
>   restart_lsn = slot->data.restart_lsn;
>   invalidated = slot->data.invalidated != RS_INVAL_NONE;
>   SpinLockRelease(&slot->mutex);
>
>   if (XLogRecPtrIsInvalid(restart_lsn) || invalidated)
>   {
>   ...
>   }
>   else if (!invalidated && !XLogRecPtrIsInvalid(restart_lsn) &&
> restart_lsn < wait_for_lsn)
>   {
>   ...
>   }
>   else
>   {
>     Assert(restart_lsn >= wait_for_lsn);
>   }
> }
>

+1.

-- 
With Regards,
Amit Kapila.



Commits

  1. Doc: Add the new section "Logical Replication Failover".

  2. Fix the review comments and a bug in the slot sync code.

  3. Fix a test in failover slots regression test.

  4. Fix the intermittent buildfarm failures in 040_standby_failover_slots_sync.

  5. Split XLogCtl->LogwrtResult into separate struct members

  6. Ensure that the sync slots reach a consistent state after promotion without losing data.

  7. Introduce a new GUC 'standby_slot_names'.

  8. Fix BF failure introduced by commit b3f6b14cf4.

  9. Fixups for commit 93db6cbda0.

  10. Fix BF failure in commit 93db6cbda0.

  11. Add a new slot sync worker to synchronize logical slots.

  12. Improve ERROR/LOG messages added by commits ddd5f4f54a and 7a424ece48.

  13. Disable autovacuum on primary in 040_standby_failover_slots_sync test.

  14. Fix the incorrect format specifier used in commit 7a424ece48.

  15. Change the LOG level in 040_standby_failover_slots_sync.pl to DEBUG2.

  16. Add more LOG and DEBUG messages for slot synchronization.

  17. Another try to fix BF failure introduced in commit ddd5f4f54a.

  18. Fix BF introduced in commit ddd5f4f54a.

  19. Add a slot synchronization function.

  20. Clean-ups for 776621a5e4 and 7329240437.

  21. Enhance libpqrcv APIs to support slot synchronization.

  22. Add a failover option to subscriptions.

  23. Allow setting failover property in the replication command.

  24. Allow to enable failover property for replication slots via SQL API.

  25. Add macros for looping through a List without a ListCell.

  26. Track conflict_reason in pg_replication_slots.

  27. Allow upgrades to preserve the full subscription's state.

  28. Add support for incremental backup.

  29. Simplify some logic in CreateReplicationSlot()

  30. Fix uninitialized access to InitialRunningXacts during decoding after ERROR.

  31. Flexible options for CREATE_REPLICATION_SLOT.

  32. Empty search_path in logical replication apply worker and walsender.

  33. Fix oldest xmin and LSN computation across repslots after advancing