When checking for datetime field overflow, we should allow a fractional-second

Tom Lane <tgl@sss.pgh.pa.us>

Commit: d2d9bd0e04a4b744117ba4edfedb9b3ee441a7be
Author: Tom Lane <tgl@sss.pgh.pa.us>
Date: 2009-05-01T19:29:27Z
Releases: 8.1.18
When checking for datetime field overflow, we should allow a fractional-second
part that rounds up to exactly 1.0 second.  The previous coding rejected input
like "00:12:57.9999999999999999999999999999", with the exact number of nines
needed to cause failure varying depending on float-timestamp option and
possibly on platform.  Obviously this should round up to the next integral
second, if we don't have enough precision to distinguish the value from that.
Per bug #4789 from Robert Kruus.

In passing, fix a missed check for fractional seconds in one copy of the
"is it greater than 24:00:00" code.

Broken all the way back, so patch all the way back.

Files

PathChange+/−
src/backend/utils/adt/datetime.c modified +12 −12