Remove wrong CloseHandle() call.

Noah Misch <noah@leadboat.com>

Commit: a9265258af9597f3a69bcb8dadfc94cc6afdf0c7
Author: Noah Misch <noah@leadboat.com>
Date: 2016-12-03T20:47:49Z
Releases: 9.2.20
Remove wrong CloseHandle() call.

In accordance with its own documentation, invoke CloseHandle() only when
directed in the documentation for the function that furnished the
handle.  GetModuleHandle() does not so direct.  We have been issuing
this call only in the rare event that a CRT DLL contains no "_putenv"
symbol, so lack of bug reports is uninformative.  Back-patch to 9.2 (all
supported versions).

Christian Ullrich, reviewed by Michael Paquier.

Files

PathChange+/−
src/port/win32env.c modified +0 −1