Remove wrong CloseHandle() call.

Noah Misch <noah@leadboat.com>

Commit: 4c3505eb46779a2d4ea55b731736b994a0f3eb49
Author: Noah Misch <noah@leadboat.com>
Date: 2016-12-03T20:47:31Z
Releases: 9.3.16
Remove wrong CloseHandle() call.

In accordance with its own documentation, invoke CloseHandle() only when
directed in the documentation for the function that furnished the
handle.  GetModuleHandle() does not so direct.  We have been issuing
this call only in the rare event that a CRT DLL contains no "_putenv"
symbol, so lack of bug reports is uninformative.  Back-patch to 9.2 (all
supported versions).

Christian Ullrich, reviewed by Michael Paquier.

Files

PathChange+/−
src/port/win32env.c modified +0 −1