v8-0001-Add-quotes-for-GUCs-bool.patch
application/octet-stream
Filename: v8-0001-Add-quotes-for-GUCs-bool.patch
Type: application/octet-stream
Part: 0
Message:
Re: GUC names in messages
Patch
Format: format-patch
Series: patch v8-0001
Subject: Add quotes for GUCs - bool
| File | + | − |
|---|---|---|
| src/backend/replication/logical/slotsync.c | 2 | 2 |
| src/test/recovery/t/040_standby_failover_slots_sync.pl | 1 | 1 |
From 4976951ec45455f14f03e10f952c514d920e8f68 Mon Sep 17 00:00:00 2001
From: Peter Smith <peter.b.smith@fujitsu.com>
Date: Tue, 11 Jun 2024 11:08:52 +1000
Subject: [PATCH v8] Add quotes for GUCs - bool
---
src/backend/replication/logical/slotsync.c | 4 ++--
src/test/recovery/t/040_standby_failover_slots_sync.pl | 2 +-
2 files changed, 3 insertions(+), 3 deletions(-)
diff --git a/src/backend/replication/logical/slotsync.c b/src/backend/replication/logical/slotsync.c
index 56d3fb5..2c60a84 100644
--- a/src/backend/replication/logical/slotsync.c
+++ b/src/backend/replication/logical/slotsync.c
@@ -1074,7 +1074,7 @@ ValidateSlotSyncParams(int elevel)
ereport(elevel,
/* translator: %s is a GUC variable name */
errcode(ERRCODE_INVALID_PARAMETER_VALUE),
- errmsg("slot synchronization requires %s to be enabled",
+ errmsg("slot synchronization requires \"%s\" to be enabled",
"hot_standby_feedback"));
return false;
}
@@ -1126,7 +1126,7 @@ slotsync_reread_config(void)
{
ereport(LOG,
/* translator: %s is a GUC variable name */
- errmsg("slot sync worker will shutdown because %s is disabled", "sync_replication_slots"));
+ errmsg("slot sync worker will shutdown because \"%s\" is disabled", "sync_replication_slots"));
proc_exit(0);
}
diff --git a/src/test/recovery/t/040_standby_failover_slots_sync.pl b/src/test/recovery/t/040_standby_failover_slots_sync.pl
index 3b6dddb..eca0b24 100644
--- a/src/test/recovery/t/040_standby_failover_slots_sync.pl
+++ b/src/test/recovery/t/040_standby_failover_slots_sync.pl
@@ -529,7 +529,7 @@ $standby1->wait_for_log(
qr/slot sync worker will restart because of a parameter change/,
$log_offset);
$standby1->wait_for_log(
- qr/slot synchronization requires hot_standby_feedback to be enabled/,
+ qr/slot synchronization requires "hot_standby_feedback" to be enabled/,
$log_offset);
$log_offset = -s $standby1->logfile;
--
1.8.3.1